The shaded PVs increase up to 21.10% power generation under a whole day radiation
Testing environment
MPPT1 and MPP2 have the same occlusion conditions: 4 blocks each, with 50% occlusion per block. MPPT1 has an optimizer installed, while MPPT2 has no optimizer installed
Test PVs
CEC6-4-60-280MD、SG-60PB-300M(10pcs, 2.9KWp)
Inverters
SH6.0RT-20, String inverter
Optimizers
SolarPilot SP1-600W-AS (10 pcs), 8.9% installed
more →
Shaded increase up to 9.6% power generation
Power
376.2KW (total 4520pcs PV modules)
Test PVs
JAM72D40-570/GB (128pcs, 72.96KWp)
Inverters
GC1-80K-5G-MAX/1100V
Optimizers
SP1-600W-AS (20 pcs), 15.63% installed
more →
Power
770.55KW (total 4520pcs PV modules)
Test PVs
JA Solar 550W (224pcs, 123.2KWp)
Inverters
Solis 110KW, String inverter
Optimizers
SP1-600W-AS (18 pcs), 8.04% installed
more →
The shaded PVs increase up to 34.17% power generation under a whole day radiation
Power
5998.23KW (total 17871pcs PV modules)
Test PVs
ReneSolar 450W (650pcs, 292.5KWp)
Inverters
Solis 230KW/1500V, String inverter
Optimizers
SP1-600W-AS(58 pcs), 8.9% installed
more →
Overall increase up to 2.27% power generation
Shaded increase up to 6.11% power generation
Power
1197KW (total 4520pcs PV modules)
Test PVs
ReneSolar JC265M-Bcb (120pcs, 31.8KWp)
Inverters
Solis GCI-30K-5G, String inverter
Optimizers
SP1-600W-AS (38 pcs), 31.6% installed
Welcome to the Solar Pilot website. In order to provide you with a better user experience and ensure the proper functioning of the website, we use Cookie technology to collect and process information about you. This Cookie Statement will explain to you the purposes, types, and choices you have regarding the use of cookies while using the website.